亚洲狼人第一精品影视|日韩欧美国产吃瓜欧美激情第21页|五月天激情综合日本ji91av|777天堂麻豆爱综合视频

歡迎來到匠仁醫療設備有限公司網站!

更多 > 新聞資訊
公司新聞
行業知識
檢測答疑
圖標 首頁 >> 新聞資訊 > 檢測答疑

檢測答疑

內窺鏡的光電耦合器出現損壞怎么處理?

來源:http://www.dcgr.cn/ 發布時間:2022-04-23 瀏覽量:0

  對于內窺鏡的光電耦合器,了解的人并不是很多,所以如果您有需求要使用該設備進行工作或者做其他事情的話,就要提前先了解好相關知識才行。那么內窺鏡的光電耦合器出現損壞怎么處理呢?
  For the photoelectric coupler of endoscope, not many people know, so if you need to use the equipment to work or do other things, it is necessary to understand the relevant knowledge in advance. So how to deal with the damage of the photoelectric coupler of endoscope?
  內窺鏡光電耦合器是內窺鏡的主要部件,作為一個微型攝像系統,它對水蒸氣非常敏感,而內窺鏡的診斷、和清潔總是在液體環境中進行,所以如果每個環節的內管和外皮損壞,就會失去密封性,液體進入后容易損壞光電耦合器就會發生損壞。
  Endoscopic photoelectric coupler is a major part of the endoscope, as a miniature camera system, it is very sensitive to water vapor, and endoscopic diagnosis, disinfection and cleaning is always in liquid environment, so if the inner tube and skin of each link is damaged, will lose tightness, easily damaged after liquid into the photoelectric coupler damage will occur.
  內窺鏡的光電耦合器出現損壞可以這樣處理,插入部分的前端主要用橡膠包裹,為減少硬物與器械的碰撞,避免磨損,需要在進出鏡頭時減少內窺鏡與口墊之間的外觀摩擦。由于內窺鏡結構精密,取出尖銳異物時,異物不能離鏡面太近,以免刺破、劃傷內窺鏡。
  The photoelectric coupler of endoscope can be damaged in this way, the front end of the inserted part is mainly wrapped with rubber, in order to reduce the collision of hard objects and instruments, avoid wear, need to reduce the appearance of friction between the endoscope and the mouth pad in and out of the lens. Because the endoscope tip structure is precise, when taking out the sharp foreign body, the foreign body can not be too close from the mirror, so as not to puncture and scratch the endoscope.
  內窺鏡的鏡身主要是合成物脂保護層,和內部、外界隔絕,若出現漏氣,則水、分泌物和黏液會進入內部,會對內窺鏡結構造成腐蝕。因此若內窺鏡損壞可以盡早發現,則需要每日對其進行檢查,及時進行側漏,若出現漏氣需要及時取出內窺鏡吹干,并且及時進行內窺鏡設備維修工作。
  The endoscopic body is mainly synthetic lipid protective layer, and the internal and external isolation, if there is air leakage, water, secretions and mucus will enter the internal, will cause corrosion of the endoscope structure. Therefore, if the endoscope damage can be found as soon as possible, it is necessary to check it every day and carry out side leakage in time. If there is air leakage, it is necessary to remove the endoscope in time and blow dry it, and carry out maintenance of endoscope equipment in time.
  此外,內窺鏡經過長期的手術室儀器設備維修,發現內窺鏡故障根據維修難易和故障大小,可分為復雜故障、中等故障和簡單故障。無論何種故障都須懂得內窺鏡的工作原理,憑借豐富的維修經驗技術處理。
  In addition, after long-term maintenance of instruments and equipment in the operating room, endoscope faults were found to be classified into complex faults, moderate faults and simple faults according to the difficulty of maintenance and the size of the faults. No matter what kind of failure must understand the working principle of endoscope, with rich maintenance experience and technology.
  內窺鏡的光電耦合器出現損壞怎么處理?看完內容應該有所了解了,當然如果您還存在疑惑的話,可以隨時通過網站www.dcgr.cn聯系到我們,我們將有的工作人員為您在線解答疑惑!
  How to deal with the damage of the photoelectric coupler of endoscope? After reading the content should have some understanding, of course, if you still have doubts, you can contact us at any time through the website www.dcgr.cn, we will have professional staff to answer your doubts online!
s
新聞資訊
聯系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯系人:樊經理
  • 電話:13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室
  • 匠仁醫療湖南長沙維修部
  • 聯系人:李經理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
新聞資訊

樊經理:13153199508     李經理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室  湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室

     

魯公網安備 37010402441281號