亚洲狼人第一精品影视|日韩欧美国产吃瓜欧美激情第21页|五月天激情综合日本ji91av|777天堂麻豆爱综合视频

歡迎來到匠仁醫療設備有限公司網站!

更多 > 新聞資訊
公司新聞
行業知識
檢測答疑
圖標 首頁 >> 新聞資訊 > 檢測答疑

檢測答疑

內窺鏡設備送水送氣不順暢是怎么回事?

來源:http://www.dcgr.cn/ 發布時間:2022-04-16 瀏覽量:0

  內窺鏡設備如今在醫療行業中頻繁的應用,使用時間久了自然而然的會出現一些小問題,比如說突然出現了設備送水送氣不順暢了,那么這是怎么回事呢?下面來講講吧。
  Endoscope equipment is now frequently used in the medical industry. After a long time of use, there will naturally be some small problems, such as the sudden emergence of the equipment to send water and air is not smooth, so what is going on? So let's talk about it.
  內窺鏡設備送水送氣不順暢的原因有幾個,比如:水瓶接口的O型圈損壞、老化、丟失,將水倒入送風管。水瓶蓋內的O型圈丟失或損壞,導致氣體流出水平儀。除此之外,水太滿或水瓶沒有擰緊。主機氣泵未開啟,內窺鏡與主機未按相應要求連接牢固,無法將空氣輸送內窺鏡管路。內窺鏡使用后不能及時床邊清洗,或前內窺鏡未及時徹底清洗,導致蛋白凝固。不合理的清潔保養造成供水、供氣按鈕損壞。
  There are several reasons why the water and air supply of endoscope equipment is not smooth, such as damage, aging and loss of the O-ring of the water bottle interface, and pouring water into the air supply pipe. The O-ring inside the bottle lid is missing or damaged, causing gas to flow out of the level. In addition, the water is too full or the bottle is not tightened. The air pump of the main machine is not opened, and the endoscope and the main machine are not firmly connected according to the corresponding requirements, so the air cannot be transported to the endoscope pipeline. The endoscope can not be cleaned bedside in time after use, or the endoscope is not cleaned thoroughly in time before disinfection, resulting in protein coagulation. Unreasonable cleaning and maintenance caused water supply and gas supply button damage.
  那針對原因,我們使用設備時應該要怎么處理?檢查水瓶接口和水瓶蓋內的O型圈,看是否損壞或丟失。如果出現相應的問題,需要及時更換。及時擰緊水瓶以免漏氣,水瓶內的水不要太滿,需要儲存適量的空氣。打開氣泵,內窺鏡與主機的連接需要穩定。如果送風按鈕和供水按鈕損壞,需要及時更換。內窺鏡應用后,需要立即在床邊進行清潔。清洗時,應將轉爐與給水、供氣管道一起清洗,管道的供氣和供水應重復15秒。床頭清洗完成后,需要立即發送設備,可以去室進行。
  So what should we do when we use the equipment for that reason? Check the bottle connector and o-ring inside the lid for damage or missing. If any problem occurs, replace it in time. Tighten the water bottle in time to avoid air leakage, the water in the bottle is not too full, need to store the right amount of air. Open the air pump, the connection between the endoscope and the host machine needs to be stable. If the air supply button and water supply button are damaged, replace them in time. Bedside cleaning is required immediately after endoscope application. When cleaning, the converter should be cleaned together with the water supply and gas supply pipeline, and the gas supply and water supply of the pipeline should be repeated for 15 seconds. After cleaning the head of the bed, it is necessary to send the equipment immediately and go to the disinfection room for disinfection.
  內窺鏡設備維修事項也要提前做好工作才行,操作人員應該及時發現故障,通過系統分析,找出發生故障的原因,掌握排除故障的方法,恢復內窺鏡設備的技術狀態非常重要。
  Endoscopic equipment maintenance matters should also do a good job in advance, the operator should find out the fault in time, through system analysis, find out the cause of the fault, master the method of troubleshooting, restore the technical state of endoscopic equipment is very important.
  內窺鏡設備送水送氣不順暢是怎么回事?以上就是相關內容的講解了。如果您對此還有疑問的話,不妨點擊網址www.dcgr.cn直接來聯系我們進行咨詢!
  Is endoscope equipment to send water to send air not smooth how to return a responsibility? The above is the explanation of relevant content. If you have any questions about this, please click on the website www.dcgr.cn to contact us directly for consultation!
s
新聞資訊
聯系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯系人:樊經理
  • 電話:13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室
  • 匠仁醫療湖南長沙維修部
  • 聯系人:李經理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
新聞資訊

樊經理:13153199508     李經理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室  湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室

     

魯公網安備 37010402441281號