內窺鏡校準前做什么檢查工作?

來源:http://www.dcgr.cn/ 發布時間:2022-03-18 瀏覽量:0

內窺鏡在檢查使用之前肯定要進行必要的校準工作才能在后期的檢查中提高精準度,下面濟南內窺鏡設備就來說說內窺鏡校準前檢查工作
The endoscope must be calibrated before use in order to improve the accuracy in the later inspection. Next, Jinan endoscope equipment will talk about the inspection before endoscope calibration
1、在足夠的照明下觀察內窺鏡外表面,應平整光滑無劃痕毛刺電鍍件表面應色澤均勻一致,不應有明顯的擦傷燒痕和可見的裂紋針孔麻點斑點毛刺油漆或噴塑件表面應平整光滑,色澤均勻,不應有露底起泡剝離開裂等現象。
1. Observe the external surface of the endoscope under sufficient lighting. It shall be flat and smooth without scratches and burrs. The surface of electroplated parts shall be uniform in color, without obvious scratches, burns and visible cracks. The surface of paint or plastic sprayed parts shall be flat and smooth, uniform in color, without bottom exposure, blistering, peeling and cracking.
2、照明光斑在正常工作距離處,在被測端放置一張白板,用浸透射光或內窺鏡自帶光源照明,從目鏡或監視器中用肉眼進行觀察照明光斑應充滿視場,無明顯的亮暗區域。
2. At the normal working distance of the lighting spot, a white board is placed at the tested end, which is illuminated with saturated light or the light source of the endoscope. It is observed with the naked eye from the eyepiece or monitor. The lighting spot should be full of the field of view without obvious bright and dark areas.
3、視場光欄方向標記(適用于纖維內窺鏡)在正常工作距離處,在被測端放置一張白板,用浸透射光或內窺鏡自帶光源照明,從目鏡看去,視場光欄箭頭指示方向標記的方向應在上方。
3. Field light bar direction mark (applicable to fiber endoscope) at the normal working distance, place a white board at the tested end and illuminate it with saturated light or the endoscope's own light source. When viewed from the eyepiece, the direction indicated by the arrow on the field light bar shall be above.
4、脫膠或霉斑在正常工作距離處,在被測端放置一張白板,用浸透射光或內窺鏡自帶光源照明,從目鏡或監視器中用肉眼進行觀察,不應有明顯的脫膠或霉斑現象。
4. Degumming or mildew at the normal working distance, place a white board at the tested end, illuminate with saturated light or the light source of the endoscope, and observe with the naked eye from the eyepiece or monitor. There should be no obvious degumming or mildew.
匠仁醫療設備(http://www.dcgr.cn)有限公司,經過多年的維修技術經驗的積累已成為內窺鏡設備維修及周邊手術器械維修服務的公司
Jiangren medical equipment( http://www.dcgr.cn )Ltd., after years of experience in maintenance technology, has become a company providing maintenance services for endoscope equipment and peripheral surgical instruments
s
新聞資訊
聯系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯系人:樊經理
  • 電話:13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室
  • 匠仁醫療湖南長沙維修部
  • 聯系人:李經理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
新聞資訊

樊經理:13153199508     李經理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室  湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室

     

魯公網安備 37010402441281號