醫療器械內窺鏡設備維修主要關鍵點

來源:http://www.dcgr.cn/ 發布時間:2022-09-20 瀏覽量:0

醫療器械內窺鏡設備維修主要關鍵點有什么呢?實際上醫療器械內窺鏡設備維修檢測設備包裝強度檢測包括包裝資料抗拉強度、復合膜剝離強度、熱封強度、撕裂強度、耐穿刺強度等指標。下面小編為您解答更多內容。
What are the main key points in the maintenance of medical instruments and endoscope equipment? In fact, the inspection of packaging strength of medical instrument endoscope equipment maintenance and inspection equipment includes tensile strength of packaging materials, peeling strength of composite film, heat sealing strength, tear strength, puncture resistance strength and other indicators. The following sections will answer more questions for you.
抗拉強度是指資料在拉斷前接受大應力值,經過檢測可以有效處理由于所選用的包裝資料機械強度不夠,而在遭到外力作用下產生的包裝破損與斷裂。
Tensile strength refers to the fact that the materials are subject to large stress values before being pulled off. After testing, it can effectively deal with the packaging damage and fracture caused by external forces due to insufficient mechanical strength of the selected packaging materials.
剝離強度也被稱作復合強度,醫療器械內窺鏡設備維修是檢測復合膜中的層與層間的粘接強度,假如粘強渡過低,則易在包裝運用中呈現層間別離而產生的泄露等問題。
Peel strength is also called composite strength. The maintenance of medical instrument endoscope equipment is to detect the adhesive strength between layers in the composite film. If the adhesive strength is too low, it is easy to present problems such as leakage caused by layer separation in packaging application.
熱封強度是檢測封口的強度,在產品的保管和運輸過程中,一旦熱封強度太低,則會招致熱封處裂開、內容物走漏等問題。耐穿刺性能是對包裝抗硬物刺穿才能停止評價的指標。
The heat sealing strength is used to detect the sealing strength. In the process of product storage and transportation, if the heat sealing strength is too low, it will lead to cracks at the heat seal, leakage of contents and other problems. Puncture resistance is an index to evaluate the puncture resistance of packaging to hard objects.
內窺鏡設備維修
醫療器械內窺鏡設備維修檢查毛病的根本辦法是先外后內,先簡單后復雜,先電源后電路,再檢查電路中的插頭及詳細單元。還能夠依據數控系統的報警信息提示,檢查設備報警提示的相關局部,能夠經過系統的參數及檢測功用,查看設備的運轉狀況,負載,電流等狀態,逐漸減少毛病范圍,終肯定毛病點,經過修復和改換之后,消弭毛病。
The basic way to repair and check the defects of medical instrument endoscope equipment is to go from outside to inside, from simple to complex, from power supply to circuit, and then check the plugs and detailed units in the circuit. It can also check the relevant parts of the equipment alarm prompt according to the alarm information prompt of the numerical control system. It can check the operating condition, load, current and other states of the equipment through the system parameters and detection functions, gradually reduce the range of faults, finally identify the fault points, and eliminate the faults after repair and replacement.
我們在醫療器械內窺鏡設備維修的時分,要留意穿插感染的問題。例如:
We should pay attention to the problem of interpenetration infection when maintaining the medical instrument endoscope. For example:
體液檢驗設備因不標準操作濺出的體液對儀器外表的污染、試劑對儀器外表的污染、激光類設備時殘留的外皮細胞對儀器外表的污染、放化療設備放射性粉塵的污染、環境的污染、維修工具的污染等。
The body fluid splashed out by the body fluid testing equipment due to non-standard operation pollutes the appearance of the instrument, the reagent pollutes the appearance of the instrument, the residual skin cells during the treatment of laser therapy equipment pollute the appearance of the instrument, the radioactive dust pollution of radiochemotherapy equipment, the environmental pollution, and the pollution of maintenance tools.
在維修此類設備時,要留意,好戴一次性手套,避免濺出的尿液、血液、激光后殘留的外皮細胞、放射性粉塵等對皮膚的接觸。維修工作完成后,要用肥皂水清洗暴露的皮膚,同時,對所運用的工具要停止清洗、。更多相關事項就來我們網站http://www.dcgr.cn咨詢吧!
During maintenance of such equipment, pay attention to wearing disposable gloves to avoid contact with skin by splashed urine, blood, residual skin cells after laser treatment, radioactive dust, etc. After the maintenance is completed, wash the exposed skin with soap and water, and stop cleaning and disinfection of the tools used. Come to our website for more information http://www , jiangrenyiliao, cn!
s
新聞資訊
聯系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯系人:樊經理
  • 電話:13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室
  • 匠仁醫療湖南長沙維修部
  • 聯系人:李經理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
新聞資訊

樊經理:13153199508     李經理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室  湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室

     

魯公網安備 37010402441281號