怎樣確定內窺鏡是否有問題?

來源:http://www.dcgr.cn/ 發布時間:2020-05-08 瀏覽量:0

內窺鏡能夠有效的提高工作人員檢查設備問題效率,可以檢查部件內部的腐蝕、銹斑、鐵屑異物、對接焊縫等質量缺陷等。那么它是怎樣確定設備存在的問題呢?從下述幾個方面可知設備出現了問題。
The endoscope can effectively improve the efficiency of the staff to check the equipment problems, and can check the quality defects such as corrosion, rust spots, iron scraps, foreign matters, butt welds and so on. So how does it identify the problem with the device? It can be seen from the following aspects that the equipment has problems.
1、裂紋
1. Crack
光束照射到被檢測物體表面時,觀察到黑色或者亮色線條,而且放大一定倍數,發現線條周圍有不規則邊緣時,可判定為裂紋。
When the light beam irradiates the surface of the detected object, black or bright lines are observed, and the magnification is a certain multiple. When irregular edges are found around the lines, it can be determined as cracks.
2、腐蝕
2. Corrosion
光束照射下,觀察有塊狀、點狀不光滑表面,在一定放大倍數下輕微凹凸不平為腐蝕。
Under the irradiation of light beam, it is observed that there are lumpy and spotty unsmooth surfaces. Under a certain magnification, slight unevenness is corrosion.
內窺鏡設備維修
3、焊漏
3. Weld leakage
光束以合適角度照射時,觀察到與熔化金屬相連,無分界線的凸起時則為焊漏。
When the beam is irradiated at an appropriate angle, it is observed that it is connected with the molten metal, and when there is no bulge at the boundary, it is a welding leak.
4、起皮
4. Flaking
當光束平行照射時,發現在凸起部分背后有陰影;改變光束照射角度,則發現表面凸起部分與周圍被檢測物  有明顯分界線,則可判定為起皮。
When the light beam is irradiated in parallel, it is found that there is shadow behind the convex part; when the light beam irradiation angle is changed, it is found that there is a clear boundary between the convex part of the surface and the surrounding detected object, it can be judged as peeling.
5、拉線和劃痕
5. Stay wire and scratches
在光束照射下,如發現被測物表面存在較規則的連續性長線,判定為拉線。
Under the illumination of the beam, if it is found that there is a relatively regular continuous long line on the surface of the measured object, it is determined as a stay wire.
6、斑點
6. Speckles
在光束照射時,觀察到與周圍被檢物色澤不同的光滑無凹凸表面可判定為斑點。
When the light beam irradiates, it is observed that the smooth non concave and convex surface with different color from the surrounding objects can be identified as spots.
關于內窺鏡設備維修http://www.dcgr.cn就先介紹到這里了,相信大家在實際的工作中會用到相關知識,如果您有這方面的需要,歡迎前來選購。
About the maintenance of endoscope equipment http://www.dcgr.cn, I'm sure you will use the relevant knowledge in the actual work. If you have this need, welcome to purchase.
s
新聞資訊
聯系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯系人:樊經理
  • 電話:13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室
  • 匠仁醫療湖南長沙維修部
  • 聯系人:李經理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
新聞資訊

樊經理:13153199508     李經理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室  湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室

     

魯公網安備 37010402441281號